Units & Measurements
In a Vernier calipers, when both jaws touch each other, zero of the Vernier scale is shifted to the right of zero of the main scale and Vernier division coincides with a main scale reading. If the value of 1 main scale division is 1 mm and there are 10 Vernier scale divisions, then the Vernier caliper has
Dimensions of universal gravitational constant () in terms of Planck's constant (), distance (), mass () and time () are _______.
The time period of a simple harmonic oscillator is . Measured value of mass of the object is 10 g with an accuracy of 10 mg and time for 50 oscillations of the spring is found to be 60 s using a watch of 2 s resolution. Percentage error in determination of spring constant is ________%.
When both jaws of vernier callipers touch each other, zero mark of the vernier scale is right to zero mark of main scale, mark on vernier scale coincides with certain mark on the main scale. While measuring the length of a cylinder, observer observes 15 divisions on main scale and division of vernier scale coincides with a main scale division. Measured length of cylinder is mm.
(Least count of Vernier calliper )
If and represent the free space permittivity, electric field and time respectively, then the unit of will be :
In an experiment the values of two spring constants were measured as and . If these springs are connected in parallel, then the percentage error in equivalent spring constant is :

A new unit ( ) of length is chosen such that it is equal to the speed of light in vacuum. What is the distance between Venus and Earth in terms of units if light takes 6 min. 40 s to cover this distance?
Consider the equation
Where magnetic field; electric field, permittivity, distance, time The values of and respectively are :
The percentage error in the calculated volume of a sphere, if there is error in its diameter measurement, is .
| A. | Boltzmann constant | I. | |
| B. | Stefan's constant | II. | |
| C. | Planck's constant | III. | |
| D. | Gravitational constant | IV. | |
Choose the correct answer from the options given below :
The density of a uniform cylinder is determined by measuring its mass , length and diameter . The measured values of and are , and , respectively. Calculated percentage fractional error in is .
The potential energy of a particle changes with distance from a fixed origin as , where and are constant with appropriate dimensions. The dimensions of are
| A. | Meter (L) | I. | |
| B. | Second (S) | II. | |
| C. | Kilogram (M) | III. | |
| D. | Kelvin (K) | IV. | |
where h (Planck's constant), G (gravitational constant) and c (speed of light in vacuum) as fundamental units.
Choose the correct answer from the options given below :
In an experiment to determine the resistance of a given wire using Ohm's law, the voltmeter and ammeter readings are noted as 10 V and 5 A , respectively. The least counts of voltmeter and ammeter are 500 mV and 200 mA , respectively. The estimated error in the resistance measurement is
and represents physical quantities inductance, capacitance and resistance respectively. The dimensional formula corresponds to .
| List - I |
List - II |
||
|---|---|---|---|
| A. | Planck's constant | I. | |
| B. | Stopping potential | II. | |
| C. | Work function | III. | |
| D. | Threshold frequency | IV. | |
Choose the correct answer from the options given below:
In a screw gauge when the circular scale is given five complete rotations it moves linearly by 2.5 mm . If the circular scale has 100 divisions, the least count of screw gauge is mm.
In a screw gauge the zero of main scale reference line coincides with the fifth division of the circular scale when two studs are in contact. There are 100 divisions in circular scale and pitch of screw gauge is 0.1 mm. When diameter of a sphere is measured, the reading of main scale is 5 mm and 50th division of circular scale coincides with the reference line of main scale. The diameter of sphere is ______ mm.
The dimensional formula of ( = permittivity of vacuum and = electric field) is .
The value of ________.
The diameter of a wire measured by a screw gauge of least count 0.001 cm is 0.08 cm. The length measured by a scale of least count 0.1 cm is 150 cm. When a weight of 100 N is applied to the wire, the extension in length is 0.5 cm, measured by a micrometer of least count 0.001 cm. The error in the measured Young’s modulus is . The value of is ________.
(Ignore the contribution of the load to Young’s modulus error calculation)
The speed of a longitudinal wave in a metallic bar is 400 m/s. If the density and Young's modulus of the bar material are increased by 0.5% and 1%, respectively then the speed of the wave is changed approximately to ______ m/s.
Match List - I with List - II.
| List – I | List – II |
|---|---|
|
A. Coefficient of viscosity B. Surface tension C. Pressure D. Surface energy |
I. [ML−1T−2] II. [ML2T−2] III. [ML0T−2] IV. [ML−1T−1] |
Choose the correct answer from the options given below :
In an experiment, a set of reading are obtained as follows - 1.24 mm, 1.25 mm, 1.23 mm, 1.21 mm. The expected least count of the instrument used in recording these readings is _______ mm.
In a vernier callipers, 50 vernier scale divisions are equal to 48 main scale divisions. If one main scale division , then the least count of the vernier callipers is mm.
In a screw gauge, the zero of the circular scale lies 3 divisions above the horizontal pitch line when their metallic studs are brought in contact. Using this instrument thickness of a sheet is measured. If pitch scale reading is 1 mm and the circular scale reading is 51 then the correct thickness of the sheet is mm.
[Assume least count is 0.01 mm ]
Four persons measure the length of a rod as and 18.25 cm . The relative error in the measurement of average length of the rod is :
| List-I | List-II | ||
| A. | Spring constant | I. | |
| B. | Thermal conductivity | II. | |
| C. | Boltzmann constant | III. | |
| D. | Inductive reactance | IV. | |
A spherical body of radius and density falls freely through a viscous liquid having density and viscosity and attains a terminal velocity . Estimated maximum error in the quantity is : (Ignore errors associated with , and , gravitational acceleration)

Keeping the significant figures in view, the sum of the physical quantities 52.01 m, 153.2 m and 0.123 m is :
Consider a modified Bernoulli equation.
If has the dimension of time then the dimensions of and are , respectively.
A quantity Q is formulated as . X, Y, and Z are independent parameters which have fractional errors of 0.1, 0.2, and 0.5, respectively in measurement. The maximum fractional error of Q is
The dimension of is equal to that of:
( = Vacuum permeability and = Vacuum permittivity)
Match List - I with List - II.
| List - I | List - II |
|---|---|
| (A) Mass density | (I) [ML2T−3] |
| (B) Impulse | (II) [MLT−1] |
| (C) Power | (III) [ML2T0] |
| (D) Moment of inertia | (IV) [ML−3T0] |
Choose the correct answer from the options given below :
In an electromagnetic system, a quantity defined as the ratio of electric dipole moment and magnetic dipole moment has dimension of . The value of P and Q are :
For the determination of refractive index of glass slab, a travelling microscope is used whose main scale contains 300 equal divisions equals to 15 cm . The vernier scale attached to the microscope has 25 divisions equals to 24 divisions of main scale. The least count (LC) of the travelling microscope is (in cm ) :
In an electromagnetic system, the quantity representing the ratio of electric flux and magnetic flux has dimension of , where value of ' ' and ' ' are
| LIST-I |
LIST-II |
||
|---|---|---|---|
| A. | I | ||
| B | II | ||
| C | III | ||
| D | IV | ||
A person measures mass of 3 different particles as and 0.125 g . According to the rules for arithmetic operations with significant figures, the addition of the masses of 3 particles will be.
Match List I with List II.
| List - I | List - II | ||
|---|---|---|---|
| (A) | Coefficient of viscosity | (I) | |
| (B) | Intensity of wave | (II) | |
| (C) | Pressure gradient | (III) | |
| (D) | Compressibility | (IV) |
Choose the correct answer from the options given below:
Match List - I with List - II.
| List - I | List - II |
|---|---|
| (A) Young’s Modulus | (I) M L-1 T-1 |
| (B) Torque | (II) M L-1 T-2 |
| (C) Coefficient of Viscosity | (III) M-1 L3 T-2 |
| (D) Gravitational Constant | (IV) M L2 T-2 |
Choose the correct answer from the options given below :
The pair of physical quantities not having the same dimensions is :
The expression given below shows the variation of velocity (v) with time (t),
.
The dimension of ABC is :
Match List - I with List - II.
| List - I | List - II |
|---|---|
| (A) Angular Impulse | (I) M0 L2 T-2 |
| (B) Latent Heat | (II) M L2 T-3 A-1 |
| (C) Electrical resistivity | (III) M L2 T-1 |
| (D) Electromotive force | (IV) M L3 T-3 A-2 |
Choose the correct answer from the options given below:
For an experimental expression , where all the digits are significant. Then to report the value of we should write
Match List - I with List - II
| List - I | List - II | ||
|---|---|---|---|
| (A) | Permeability of free space | (I) | |
| (B) | Magnetic field | (II) | |
| (C) | Magnetic moment | (III) | |
| (D) | Torsional constant | (IV) |
Choose the correct answer from the options given below :
The position of a particle moving on -axis is given by , where is time. The dimension of is
The maximum percentage error in the measurment of density of a wire is
[Given, mass of wire
radius of wire
length of wire
If is magnetic field and is permeability of free space, then the dimensions of is
Given below are two statements :
Statement I: In a vernier callipers, one vernier scale division is always smaller than one main scale division.
Statement II : The vernier constant is given by one main scale division multiplied by the number of vernier scale divisions.
In the light of the above statements, choose the correct answer from the options given below.
The de-Broglie wavelength associated with a particle of mass and energy is . The dimensional formula for Planck's constant is :
The dimensional formula of latent heat is :
One main scale division of a vernier caliper is equal to units. If division of main scale coincides with division of vernier scale, the least count of the vernier caliper is :
If is the permittivity of free space and is the electric field, then has the dimensions :
There are 100 divisions on the circular scale of a screw gauge of pitch . With no measuring quantity in between the jaws, the zero of the circular scale lies 5 divisions below the reference line. The diameter of a wire is then measured using this screw gauge. It is found that 4 linear scale divisions are clearly visible while 60 divisions on circular scale coincide with the reference line. The diameter of the wire is :
Least count of a vernier caliper is . The value of one division on the main scale is . Then the number of divisions of main scale that coincide with divisions of vernier scale is :
The diameter of a sphere is measured using a vernier caliper whose 9 divisions of main scale are equal to 10 divisions of vernier scale. The shortest division on the main scale is equal to . The main scale reading is and second division of vernier scale coincides with a division on main scale. If mass of the sphere is 8.635 , the density of the sphere is:
In a vernier calliper, when both jaws touch each other, zero of the vernier scale shifts towards left and its division coincides exactly with a certain division on main scale. If 50 vernier scale divisions equal to 49 main scale divisions and zero error in the instrument is then how many main scale divisions are there in ?
In finding out refractive index of glass slab the following observations were made through travelling microscope 50 vernier scale division divisions on main scale in each
For mark on paper
For mark on paper seen through slab
For powder particle on the top surface of the glass slab
(MSR Main Scale Reading, VC = Vernier Coincidence)
Refractive index of the glass slab is :
To find the spring constant of a spring experimentally, a student commits positive error in the measurement of time and negative error in measurement of mass. The percentage error in determining value of is :
Match List I with List II
| LIST I | LIST II | ||
|---|---|---|---|
| A. | Torque | I. | |
| B. | Magnetic field | II. | |
| C. | Magnetic moment | III. | |
| D. | Permeability of free space | IV. |
Choose the correct answer from the options given below:
While measuring diameter of wire using screw gauge the following readings were noted. Main scale reading is and circular scale reading is equal to 42 divisions. Pitch of screw gauge is and it has 100 divisions on circular scale. The diameter of the wire is . The value of is :
What is the dimensional formula of in the equation , where letters have their usual meaning.
A vernier callipers has 20 divisions on the vernier scale, which coincides with division on the main scale. The least count of the instrument is . One main scale division is equal to ________ mm.
Time periods of oscillation of the same simple pendulum measured using four different measuring clocks were recorded as and . The arithmetic mean of these readings in correct significant figure is :
Applying the principle of homogeneity of dimensions, determine which one is correct, where is time period, is gravitational constant, is mass, is radius of orbit.
The equation of stationary wave is :
Which of the following is NOT correct :
| List I (Number) | List II (Significant figure) |
|---|---|
| (A) 1001 | (I) 3 |
| (B) 010.1 | (II) 4 |
| (C) 100.100 | (III) 5 |
| (D) 0.0010010 | (IV) 6 |
Choose the correct answer from the options given below :
The percentage error in resistivity of the material of the wire is :
Consider two physical quantities and related to each other as where and have dimensions of energy, length and time respectively. The dimension of is
The measured value of the length of a simple pendulum is with accuracy. The time for 50 oscillations was measured to be 40 seconds with 1 second resolution. From these measurements, the accuracy in the measurement of acceleration due to gravity is . The value of is:
If the percentage errors in measuring the length and the diameter of a wire are each. The percentage error in measuring its resistance will be:
A force is represented by
where distance and time. The dimensions of are:
If 50 Vernier divisions are equal to 49 main scale divisions of a traveling microscope and one smallest reading of main scale is , the Vernier constant of traveling microscope is
If mass is written as then the value of will be : (Constants have their usual meaning with dimensionless constant)
Match List I with List II.
| List I | List II | ||
|---|---|---|---|
| (A) | Coefficient of viscosity | (I) | |
| (B) | Surface tension | (II) | |
| (C) | Angular momentum | (III) | |
| (D) | Rotational kinetic energy | (IV) |
Choose the correct answer from the options given below :
A physical quantity is found to depend on quantities by the relation . The percentage error in and are and respectively. Then, the percentage error in is :
The resistance where and , the percentage error in the measurement of is :
Given below are two statements : one is labelled as Assertion (A) and the other is labelled as Reason (R).
Assertion (A) : In Vernier calliper if positive zero error exists, then while taking measurements, the reading taken will be more than the actual reading.
Reason (R) : The zero error in Vernier Calliper might have happened due to manufacturing defect or due to rough handling.
In the light of the above statements, choose the correct answer from the options given below :
Given below are two statements :
Statement (I) : Planck's constant and angular momentum have same dimensions.
Statement (II) : Linear momentum and moment of force have same dimensions.
In the light of the above statements, choose the correct answer from the options given below :
In the equation is pressure, is volume, is universal gas constant and is temperature. The physical quantity equivalent to the ratio is:
A body of mass is moving with a velocity of . Its kinetic energy will be
Match List I with List II
| LIST I | LIST II | ||
|---|---|---|---|
| A. | Spring constant | I. | |
| B. | Angular speed | II. | |
| C. | Angular momentum | III. | |
| D. | Moment of inertia | IV. |
Choose the correct answer from the options given below:
If force (F), velocity (V) and time (T) are considered as fundamental physical quantity, then dimensional formula of density will be :
Given below are two statements :
Statements I : Astronomical unit (Au), Parsec (Pc) and Light year (ly) are units for measuring astronomical distances.
Statements II :
In the light of the above statements, choose the most appropriate answer from the options given below:

In an experiment with vernier callipers of least count , when two jaws are joined together the zero of vernier scale lies right to the zero of the main scale and 6th division of vernier scale coincides with the main scale division. While measuring the diameter of a spherical bob, the zero of vernier scale lies in between and marks, and 4th division of vernier scale coincides with the main scale division. The diameter of bob is measured as
A physical quantity P is given as
The percentage error in the measurement of a, b, c and d are 1%, 2%, 3% and 4% respectively. The percentage error in the measurement of quantity P will be
Match List I with List II
| LIST I | LIST II | ||
|---|---|---|---|
| A. | Torque | I. | |
| B. | Stress | II. | |
| C. | Pressure gradient | III. | |
| D. | Coefficient of viscosity | IV. |
Choose the correct answer from the options given below:
Dimension of should be equal to
A cylindrical wire of mass has length and radius . The maximum error in its density will be:
Two resistances are given as and . The percentage error in the measurement of equivalent resistance when they are connected in parallel is -
If the velocity of light , universal gravitational constant and Planck's constant are chosen as fundamental quantities. The dimensions of mass in the new system is :
| LIST I | LIST II | ||
|---|---|---|---|
| A. | Angular momentum | I. | |
| B. | Torque | II. | |
| C. | Stress | III | |
| D. | Pressure gradient | IV. | |
Choose the correct answer from the options given below:
Match List I with List II:
| List I | List II | ||
|---|---|---|---|
| A. | Torque | I. | |
| B. | Energy density | II. | |
| C. | Pressure gradient | III. | |
| D. | Impulse | IV. | |
Choose the correct answer from the options given below:
The equation of a circle is given by , where a is the radius. If the equation is modified to change the origin other than (0, 0), then find out the correct dimensions of A and B in a new equation : . The dimensions of t is given as .
Match List I with List II :
| List I (Physical Quantity) | List II (Dimensional Formula) | ||
|---|---|---|---|
| A. | Pressure gradient | I. | |
| B. | Energy density | II. | |
| C. | Electric Field | III. | |
| D. | Latent heat | IV. |
Choose the correct answer from the options given below:
Match List I with List II
| List I | List II | ||
|---|---|---|---|
| A. | Young's Modulus (Y) | I. | |
| B. | Co-efficient of Viscosity () | II. | |
| C. | Planck's Constant (h) | III. | |
| D. | Work function () | IV. |
Choose the correct answer from the options given below :
Match List I with List II
| List-I |
List-II |
||
|---|---|---|---|
| A. | Planck's constant (h) | I. | |
| B. | Stopping potential (Vs) | II. | |
| C. | Work function () | III. | |
| D. | Momentum (p) | IV. |
Choose the correct answer from the options given below :
Match List I with List II.
| List I | List II | ||
|---|---|---|---|
| A. | Torque | I. | Nms |
| B. | Stress | II. | J kg |
| C. | Latent Heat | III. | Nm |
| D. | Power | IV. | Nm |
Choose the correct answer from the options given below :
Given below are two statements : One is labelled as Assertion (A) and other is labelled as Reason (R).
Assertion (A) : Time period of oscillation of a liquid drop depends on surface tension (S), if density of the liquid is and radius of the drop is r, then is dimensionally correct, where K is dimensionless.
Reason (R) : Using dimensional analysis we get R.H.S. having different dimension than that of time period.
In the light of above statements, choose the correct answer from the options given below.
A travelling microscope has 20 divisions per on the main scale while its vernier scale has total 50 divisions and 25 vernier scale divisions are equal to 24 main scale divisions, what is the least count of the travelling microscope?
In an experiment to find out the diameter of wire using screw gauge, the following observations were noted :

(A) Screw moves on main scale in one complete rotation
(B) Total divisions on circular scale
(C) Main scale reading is
(D) division of circular scale is in the pitch line
(E) Instrument has 0.03 mm negative error
Then the diameter of wire is :

Consider the efficiency of carnot's engine is given by , where and are constants. If T is temperature, k is Boltzmann constant, is angular displacement and x has the dimensions of length. Then, choose the incorrect option :
The dimensions of will be :
(if : permeability of free space and : magnetic field)
An expression of energy density is given by , where are constants, is displacement, is Boltzmann constant and t is the temperature. The dimensions of will be :
A torque meter is calibrated to reference standards of mass, length and time each with accuracy. After calibration, the measured torque with this torque meter will have net accuracy of :
In a Vernier Calipers, 10 divisions of Vernier scale is equal to the 9 divisions of main scale. When both jaws of Vernier calipers touch each other, the zero of the Vernier scale is shifted to the left of zero of the main scale and Vernier scale division exactly coincides with the main scale reading. One main scale division is equal to . While measuring diameter of a spherical body, the body is held between two jaws. It is now observed that zero of the Vernier scale lies between 30 and 31 divisions of main scale reading and Vernier scale division exactly coincides with the main scale reading. The diameter of the spherical body will be :
A screw gauge of pitch is used to measure the diameter of uniform wire of length , the main scale reading is and circular scale reading is 7 . The calculated curved surface area of wire to appropriate significant figures is :
[Screw gauge has 50 divisions on its circular scale]
The maximum error in the measurement of resistance, current and time for which current flows in an electrical circuit are and respectively. The maximum percentage error in the detection of the dissipated heat will be :
If momentum [P], area and time are taken as fundamental quantities, then the dimensional formula for coefficient of viscosity is :
If n main scale divisions coincide with (n + 1) vernier scale divisions. The least count of vernier callipers, when each centimetre on the main scale is divided into five equal parts, will be :
Velocity (v) and acceleration (a) in two systems of units 1 and 2 are related as and respectively. Here m and n are constants. The relations for distance and time in two systems respectively are :
The SI unit of a physical quantity is pascal-second. The dimensional formula of this quantity will be :
A silver wire has a mass (0.6 0.006) g, radius (0.5 0.005) mm and length (4 0.04) cm. The maximum percentage error in the measurement of its density will be :
The dimension of mutual inductance is :
An expression for a dimensionless quantity P is given by ; where and are constants, x is distance; k is Boltzmann constant and t is the temperature. Then the dimensions of will be :
If , then the relative error in Z will be :
Identify the pair of physical quantities that have same dimensions:
Identify the pair of physical quantities which have different dimensions:
| Physical Quantity |
Least count of the Equipment used for measurement |
Observed value |
|---|---|---|
| Mass (M) | 1 g | 2 kg |
| Length of bar (L) | 1 mm | 1 m |
| Breadth of bar (b) | 0.1 mm | 4 cm |
| Thickness of bar (d) | 0.01 mm | 0.4 cm |
| Depression () | 0.01 mm | 5 mm |
Then the fractional error in the measurement of Y is :
| List - I | List - II | ||
|---|---|---|---|
| (a) | Torque | (i) | MLT |
| (b) | Impulse | (ii) | MT |
| (c) | Tension | (iii) | MLT |
| (d) | Surface Tension | (iv) | MLT |
Choose the most appropriate answer from the option given below :
Where t = time, h = height, s = surface tension, = angle, = density, a, r = radius, g = acceleration due to gravity, v = volume, p = pressure, W = work done, T = torque, = permittivity, E = electric field, J = current density, L = length.
| List - I | List - II | ||
|---|---|---|---|
| (a) | (Rydberg constant) | (i) | |
| (b) | h (Planck's constant) | (ii) | |
| (c) | (Magnetic field energy density) | (iii) | |
| (d) | (coefficient of viscocity) | (iv) |
Choose the most appropriate answer from the options given below :
| List-I | List-II | ||
|---|---|---|---|
| (a) | Magnetic Induction | (i) | ML2T-2A-1 |
| (b) | Magnetic Flux | (ii) | M0L-1A |
| (c) | Magnetic Permeability | (iii) | MT-2A-1 |
| (d) | Magnetization | (iv) | MLT-2A-2 |
Choose the most appropriate answer from the options given below :
If the percentage errors found in y, m, r, l and g are 18, 1, 0.5, 4 and p respectively, then find the value of x and p.
Reason R :
Least Count =
In the light of the above statements, choose the most appropriate answer from the options given below :
F = A cos Bx + C sin Dt
The dimensional formula of is :
| List I | List II | ||
|---|---|---|---|
| (a) | h (Planck's constant) | (i) | |
| (b) | E (kinetic energy) | (ii) | |
| (c) | V (electric potential) | (iii) | |
| (d) | P (linear momentum) | (iv) |
Choose the correct answer from the options given below :
given by, , where x is the displacement, k is the Boltzmann constant and T is the temperature. and are constants. Then the dimensions of will be :
of the pencil should therefore be recorded as :
defined where C-capacitance, R-Resistance, l-length, E-Electric field, B-magnetic field and , , - free space permittivity and permeability respectively. Then :
a, b, c and d, as z = . The percentages of error in the measurement of a, b, c and d are 2%, 1.5%, 4% and 2.5% respectively. The percentage of error in z is :
(i) A1 = 24.36, B1 = 0.0724, C1 = 256.2
(ii) A2 = 24.44, B2 = 16.082, C2 = 240.2
(iii) A3 = 25.2, B3 = 19.2812, C3 = 236.183
(iv) A4 = 25, B4 = 236.191, C4 = 19.5
The readings of the main scale and the circular scale, for a thin sheet, are 5.5 mm and 48 respectively, the thickness of this sheet is :
The maximum percentage error in the value of A will be :
Which of the following correctly gives the Planck length ?
P = a^{{\raise0.5ex\hbox{\scriptstyle 1} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{\scriptstyle 2}}} b2 c3 d4
If the relative errors in the measurement of a, b, c and d respectively, are 2%, 1%, 3% and 5%, then the relative error in P will be :
diameter of capillary, D = 1.25 10-2 m
rise of water, h = 1.45 10-2m
Using g = 9.80 m/s2 and the simplified relation T = , the possible error in surface tension is closest to :
Main scale reading: 58.5 degree
Vernier scale reading : 09 divisions
Given that 1 division on main scale corresponds to 0.5 degree. Total divisions on the vernier scale is 30 and match with 29 divisions of the main scale. The angle of the prism from the above data
Main scale reading : 0 mm
Circular scale reading : 52 divisions
Given that 1 mm on main scale corresponds to 100 divisions of the circular scale.
The diameter of wire from the above date is: